S11-1600KVA/35KV/10KV/0.4KV oil-immersed transformer

Source:https://www.zhongjingpower.comAuthor:adminTime:2023-12-28

With the standardization of transformer management, the layout of transformer facilities is relatively normal, which is more important is that all transformers have been installed transformer room, whether it is rural or in the city, basically achieve full coverage of the function. Transformers also have a more important basis in operation and maintenance. The transformer should pay attention to safety when running, because the existence of the transformer room has a better safety guarantee. Therefore, when the transformer is running, it is more than a security guarantee!




When the oil-immersed transformer is running, a lot of heat will be generated in the transformer room, so the heat dissipation and ventilation problems of the transformer room are the key problems to be considered in the design of the European transformer. When the transformer is running, a large amount of heat is continuously generated, so that the temperature of the transformer room continues to rise, especially when the ambient temperature is high, the temperature rises faster, so only natural ventilation and heat dissipation often cannot guarantee the reliable and safe operation of the transformer; In the design of European-style box-type substation, in addition to the natural ventilation of the box with small transformer capacity, temperature measurement protection is generally designed and solved by forced exhaust measures. The system mainly consists of measuring device, measuring transformer room temperature, oil temperature can be. Then, through the manual and automatic control circuit, whether the exhaust fan needs to be put in, according to the setting range of the transformer's reliable and safe operating temperature.


The harm of oil-immersed transformer should be noise harm, if you have experienced friends should know that the noise in the oil-immersed transformer room is still very large, especially the noise of the dry oil-immersed transformer in the residential power substation room is very large, especially at night is more obvious; Oil-immersed transformer may cause the second hazard that is the electrical radiation hazard, the radiation hazard of the oil-immersed transformer is actually very small, through the radiation isolation shielding layer, the radiation hazard of the oil-immersed transformer is almost no, unless the oil-immersed transformer has been standing next to the close contact will appear harm, The oil-immersed transformer in the community generally has a separate oil-immersed transformer room, which can completely shield the harm of radiation;


In the application design of network oil-immersed transformer, we can decide which line of network oil-immersed transformer products should be used according to the situation, if there are no other characteristics, from the cost considerations alone, we still have to give priority to a network oil-immersed transformer line, in the production reality of Huaqiang Electronics, The use of network oil-immersed transformer lines reached more than 95% of the total production,


From the difference between the voltage regulator and the oil-immersed transformer, simply from the word to understand, the voltage regulator is the fluctuation of the unstable voltage to the set value of the electrical appliance, the output voltage will not fluctuate greatly. The oil-immersed transformer is an electronic component that transforms the voltage by electromagnetism. Oil immersed transformer in the circuit mainly plays the role of rising and falling pressure.


The oil-immersed transformer is used to transform the AC voltage, which is widely used, and it can be said that all electronic products can not be separated from it as long as the mains power of 220V is used. The voltage regulator is used to stabilize the 220V mains voltage, so as not to cause damage to electrical appliances when the voltage is low or high, and is used for equipment with relatively high voltage requirements or where the mains is unstable.


The oil-immersed transformer room should not be very large, but it must not leak rain, but also be built in a spacious and unattended place, and there should always be maintenance and maintenance, if there is a problem, it should be repaired in time to effectively ensure the smooth and safe operation of the transformer!


Latest news

  1. Installation distance of dry type transformer
    2024-02-04/Company news
  2. Do not approach mine transformers during and after a rainstorm
    2024-02-04/Company news
  3. Dry transformer core rust hazards
    2024-02-04/Company news
  4. Four ways to install transformers
    2023-12-28/Company news
  5. Transformer daily inspection work
    2023-12-28/Company news
131-6513-3141